There are generally the following factors:
1. The intake air flow is too high
2. Low intake pressure
3. The intake air temperature is too high
4. Excessive water content
5. The adsorbent is contaminated with oil.
6. The filter is invalid.
7. Incorrect dew point indication
Ways to find influencing factors:
1. It means that the flow rate of compressed air into the suction dryer is greater than the standard processing capacity of the suction dryer
2. Refers to the pressure of the compressed air entering the suction dryer
3. Refers to the temperature of the compressed air entering the suction dryer
4. Refers to the saturated water content of the compressed air entering the suction dryer
5. Refers to the adsorbent in the adsorption tower
6. Refers to the working effect of the filter before and after the suction dryer
7. The installed dew point meter shows error
Solution:
1. Check the outlet air volume of the compressor
2. Control pressure
3. Check the compressor outlet
4. Check the aftercooler and pre-filter drain valve
5. Depressurize the dryer and check whether the desiccant is discolored or poisoned
6. Replace the filter element
7. Recheck
Rongjingsheng Electromechanical provides you with high-quality adsorption dryers to reduce the moisture content of your compressed air
Rongjingsheng Air compressor and aerodynamic energy saving experts around you 0710-3455557 13797571525